Clinical Investigation
Imaging features of 99Tcm-dextran lymphoscitigraphy in thoracic duct exports obstruction
Zheng Pengteng, Tong Guansheng
Published 2022-05-25
Cite as Chin J Nucl Med Mol Imaging, 2022, 42(5): 274-278. DOI: 10.3760/cma.j.cn321828-20210303-00056
Abstract
ObjectiveTo compare the 99Tcm-dextran(DX) lymphoscitigraphy and direct lymphography (DLG), in order to investigate the imaging features and clinical significance of 99Tcm-DX lymphoscitigraphy in patients with thoracic duct exports (TDE)obstruction.
MethodsA total of 304 patients (140 males, 164 females, median age: 32 years) with TDE obstruction confirmed by thoracic duct exploration between 2017-01-01 and 2019-01-01 in Beijing Shijitan Hospital were retrospectively analyzed. Based on the different imaging characteristics of TDE, the reluts of 99Tcm-DX lymphoscitigraphy were divided into five groups (Ⅰ: no TDE presenting; Ⅱ: TDE presenting temporarily; Ⅲ: TDE presenting constantly or extensively; Ⅳ: abnormal reflux of imaging agents; Ⅴ: bilateral venous angle presenting). Ⅰ/Ⅱ groups were regarded as negative and Ⅲ-Ⅴ groups as positive. The consistency of 99Tcm-DX lymphoscitigraphy with DLG was evaluated with Kappa test, and the positive rates of the two methods were compared by McNemar test.
ResultsIn the detection of TDE, the positive rate of 99Tcm-DX lymphoscintigraphy was 70.1% (213/304), which was significantly lower than that of DLG (97.4%, 296/304; χ2=4.16, P<0.001). The group Ⅲ has the largest number of cases (54.9%, 167/304), and there was a low consistency with DLG (Kappa=0.08, P=0.005). However, there was a higher consistency between 99Tcm-DX lymphoscintigraphy results and the corresponding DLG results in the groups Ⅳ/Ⅴ (Kappa values: 0.48, 0.86, both P<0.001). Furthermore, the diagnostic accordance rates of lower extremity lymphedema and chylous effusion were 96.1%(98/102) and 83.6%(127/152), respectively, compared with the clinical diagnosis.
ConclusionsTDE obstruction of 99Tcm-DX lymphoscitigraphy presents in the majority with Ⅲ type. 99Tcm-DX lymphoscitigraphy results in patients with type Ⅳ and Ⅴ have a better consistency with those of DLG. 99Tcm-DX lymphoscitigraphy can be used as a screening tool of TDE obstruction, and play a role in the diagnosis of lower limb lymphedema and chylous effusion caused by TDE obstruction.
Key words:
Catheter obstruction; Thoracic duct; Radionuclide imaging; Dextrans; Technetium; Lymphography
Contributor Information
Zheng Pengteng
Department of Nuclear Medicine, Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China
Tong Guansheng
Department of Nuclear Medicine, Beijing Shijitan Hospital, Capital Medical University, Beijing 100038, China