Coverage errors of five shade guide systems to vital natural teeth
CHEN Li, TAN Jian-guo, LIU Ming-yue, ZHOU Jian-feng, LIU Xiao-qiang
Published 2013-08-09
Cite as Chin J Stomatol, 2013,48(08): 449-452. DOI: 10.3760/cma.j.issn.1002-0098.2013.08.001
Abstract
Objective To compare the coverage errors (CE)of five different shade guides in anterio vital natural teeth of selected people.Methods Anterior vital natural teeth were measured with Crystaleye spectrophotometer,color coordinates of the teeth and five shade guides A (VITA Classical),B (VITA 3D-Master),C (Chromascop),D (Shofu Vintage Halo NCC) and E (Noritake)were analyzed with the supporting software.The CE of the five shade guide systems to natural teeth were evaluated in cervical,body and incisal regions,and difference in CE among shade guides was determined.Results In the cervical region,shade guide A had the maximal CE value (3.09 ±0.97) and shade guide D had the minimal CE value (1.62 ± 0.75).In the body region,CE of shade guide B (1.65 ± 0.64) and shade guide D (1.52 ± 0.74) were lower than those of shade guides A (2.04 ± 0.80),C (2.04 ± 0.90) and E (2.02 ± 0.84) (P < 0.05).In the incisal part,all CE were below 2.00,and again shade guide A had the maximal CE value (1.81 ± 0.86) and shade guide D had the minimal CE value (1.28 ± 0.55).Conclusions Within the limitation of the study,shade guide D had better color coverage of natural teeth in cervical,body and incisal regions.
Key words:
Tooth; Color; Shade guide; Coverage error
Contributor Information
CHEN Li
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
TAN Jian-guo
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
LIU Ming-yue
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
ZHOU Jian-feng
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China
LIU Xiao-qiang
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing 100081, China