Study on Standards for Indoor Air Quality
Study on formulation and revision of standard limits for inhalable particulate matter (PM10) and fine particulate matter (PM2.5) in “Standards for indoor air quality(GB/T 18883-2022)” in China
Li Yawei, Li Chengcheng, Chen Chen, Li Zheng, Chen Chen, Fang Jianlong, Li Tiantian, Zhao Feng, Shi Xiaoming
Published 2023-11-06
Cite as Chin J Prev Med, 2023, 57(11): 1761-1765. DOI: 10.3760/cma.j.cn112150-20230608-00451
Abstract
The pollution and health effects of indoor inhalable particulate matter (PM10) and fine particulate matter (PM2.5) are increasingly receiving public attention. The"Standards for indoor air quality (GB/T 18883-2022)"has revised the standard limit for PM10 and added the standard limit for PM2.5. This study analyzed and interpreted the relevant technical contents of the revision of the standard limits for two indicators, including the exposure status, health effects, and the basis for the determination of the limit value. It also proposed prospects for the future development and revision of standard limits for indoor particulate matters.
Key words:
PM10; PM2.5; Health risk assessment; Standard limit
Contributor Information
Li Yawei
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Li Chengcheng
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Chen Chen
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Li Zheng
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Chen Chen
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Fang Jianlong
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Li Tiantian
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Zhao Feng
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China
Shi Xiaoming
China CDC Key Laboratory of Environment and Population Health/National Institute of Environmental Health, Chinese Center for Disease Control and Prevention, Beijing 100021, China