Review
Research progress on the application of specially lense related to myopia prevention and control
Yue Pengcheng, Kong Ling, Zhang Tong, Qiao Zhentao
Published 2024-04-11
Cite as Chin J Ophthalmol, 2024, 60(4): 384-391. DOI: 10.3760/cma.j.cn112142-202230913-00098
Abstract
In order to decelerate the growth of myopia in children and adolescents and reduce the risks of associated eye complications, extensive research has been conducted on preventive measures, including optical, behavioral, and pharmaceutical interventions. Spectacle lenses, due to their safety, convenience, and high patient compliance, stand out as the most common method for correcting refractive errors compared to other interventions. As far as we know, various forms of spectacle lenses are currently used in clinical practice, including bifocal lenses, progressive multifocal lenses, peripheral defocus lenses, defocus incorporated multiple segments (DIMS) lenses, highly aspherical lenslets, diffusion optics technology lenses, and violet light transmission (VL) glasses. However, a systematic and comprehensive overview of myopia-controlling spectacle lenses is still lacking. Therefore, this article summarizes the latest research progress on the myopia prevention and control technology of spectacle lenses at home and abroad, providing theoretical support for the myopia prevention and control effect of different spectacle lens technologies, promoting the application of related technologies in clinical work, and offering new ideas for myopia prevention and control.
Key words:
Myopia; Eyeglasses; Child; Adolescent; Validation study
Contributor Information
Yue Pengcheng
Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao 266071, China
Kong Ling
Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao 266071, China
Zhang Tong
Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao 266071, China
Qiao Zhentao
Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao 266071, China