Analysis of the corneal spherical aberration of age-related cataractous eyes
Liu Wenjie
Liu Jiewei
Wang Qi
Wang Jingjing
Jia Zhijie
Wang Bing
Li Xiaorong
Authors Info & Affiliations
Liu Wenjie
Tianjin Medical University Eye Hospital, Tianjin 300384, China (is working at Shanxi Eye Hospital, Taiyuan 03001, China)
Liu Jiewei
Shanxi Eye Hospital, Taiyuan 030001, China
Wang Qi
Shanxi Eye Hospital, Taiyuan 030001, China
Wang Jingjing
Shanxi Eye Hospital, Taiyuan 030001, China
Jia Zhijie
Shanxi Eye Hospital, Taiyuan 030001, China
Wang Bing
Shanxi Eye Hospital, Taiyuan 030001, China
Li Xiaorong
Tianjin Medical University Eye Hospital, Tianjin 300384, China
·
DOI: 10.3760/cma.j.cn115989-20200325-00201
427
153
0
0
0
1
PDF下载
APP内阅读
摘要

目的观察年龄相关性白内障患者术前角膜球差的分布情况及其相关因素。

方法采用横断面研究方法,对2014年12月至2015年12月于山西省眼科医院就诊的40岁以上年龄相关性白内障患者1 319例1 319眼术前角膜球面像差进行测量,分析年龄相关性白内障患者术前角膜球面像差分布。所有患眼均采用Pentacam HR眼前节分析仪测量平均角膜曲率(Km)值、平均角膜后表面曲率(Km)值、角膜散光值、角膜后表面散光值和角膜厚度;采用Zernike分析计算以角膜顶点为中心6 mm直径范围内的角膜球面像差值;计算角膜球面像差的分布情况及其与各眼球因素之间的相关性、不同类型非球面人工晶状体矫正角膜球差的比率。

结果患者平均年龄为(68.00±11.12)岁,平均角膜球面像差值为(0.34±0.17)μm,波动范围为-0.38~0.99 μm。其中角膜球面像差<0 μm者22眼,占1.67%;角膜球面像差为0~0.4 μm者842眼,占63.84%;角膜球面像差>0.4 μm者455眼,占34.50%。角膜球面像差与患者年龄呈弱正相关( r=0.398, P<0.001);与受检眼角膜Km值、角膜后表面Km值、角膜厚度均呈极弱相关( r=0.129, P<0.001; r=0.240, P<0.001; r=-0.068, P<0.05);与角膜散光或角膜后表面散光之间尚不能认为有相关性( r=-0.025, P=0.365; r=-0.008, P=0.771)。年龄可能影响角膜球面像差。以残余球面像差(0.10±0.05)μm为目标采用不同类型非球面人工晶状体(0、-0.20和-0.27 μm)可矫正710眼,占53.83%。

结论年龄相关性白内障患者术前平均角膜球面像差较既往报道值(+0.27 μm)偏大。术前应根据患者个性化的角膜球面像差选择适合的非球面IOL。

生物测量/眼;角膜球面像差;白内障;非球面人工晶状体
ABSTRACT

ObjectiveTo investigate the distribution of the spherical aberration in age-related cataractous eyes using the Pentacam HR.

MethodsA cross-sectional study was performed in Shanxi Eye Hospital from December 2014 to December 2015.The preoperative corneal spherical aberration of 1 319 eyes of 1 319 patients with age-related cataract over 40-years-old was analyzed.The mean average keratometry (Km value), and corneal posterior surface Km corneal astigmatism, posterior corneal astigmatism, and corneal thickness were measured with.Pentacam, and the Zernike coefficients of corneal spherical aberration were calculated.A correlation between spherical aberration and corneal parameters was evaluated by Pearson correlation analysis.The proportion of eyes qualifying for spherically neutral or negatively aspheric intraocular lens targeted residual spherical aberration level was evaluated.This study protocol was approved by Ethics Committee of Shanxi Eye Hospital and complied with Declaration of Helsinki.

ResultsThe average age of all patients was (68.00±11.12) years old with an average spherical aberration (0.34±0.17)μm.The spherical aberration was lower than 0 μm in 22 eyes (1.67%), 0~0.4 μm in 842 eyes (63.84%), and greater than 0.4 μm in 455 eyes (34.50%). There was a weak positive correlation between spherical aberration and age ( r=0.398, P<0.001). There were very weak correlations between spherical aberration and corneal Km, posterior corneal surface Km, corneal thickness ( r=0.129, P<0.001; r=0.240, P<0.001; r=-0.068, P<0.05). No significant correlations were found between spherical aberration and corneal astigmatism or posterior corneal astigmatism ( r=-0.025, P=0.365; r=-0.008, P=0.771). Seven hundred and ten eyes (53.83%) could be qualified for implantation of negatively or neutrally aspheric intraocular lens based on postoperative targets of (0.10±0.05)μm residual spherical aberration.

ConclusionsCorneal spherical aberration in Chinese patients is greater than that in other populations (+ 0.27 μm) in literature and shows individual differences.The appropriate aspheric intraocular lens should be selected according to individual corneal spherical aberration before cataract operation.

Biometry/ocular;Corneal spherical aberration;Cataract;Aspherical intraocular lens
Li Xiaorong, Email: nc.defudabe.umtgnoroaixil
引用本文

刘文洁,刘杰为,王琪,等. 年龄相关性白内障患者术前角膜球面像差分析[J]. 中华实验眼科杂志,2020,38(04):336-341.

DOI:10.3760/cma.j.cn115989-20200325-00201

PERMISSIONS

Request permissions for this article from CCC.

评价本文
*以上评分为匿名评价
由球面人工晶状体(intraocular lens,IOL)增加的全眼球面像差是导致起白内障术后各种不良视觉症状的原因之一 [ 1 ]。球面像差是轴对称性高阶像差,能被IOL所矫正,目前各种不同类型的非球面IOL广泛用于白内障手术,以达到矫正角膜球面像差,提高术后视觉质量的目的 [ 2 ]。因此了解白内障患者术前角膜球面像差的分布对于适宜的非球面IOL的选择,提高患者术后的视觉质量至关重要。目前中国年龄相关性白内障人群术前角膜球面像差的分布情况报道较少,而临床工作中发现患者间术前角膜球面像差个体变异较大,值得眼科医生关注。本研究探讨年龄相关性白内障患者术前角膜球面像差的分布及其影响因素,为临床上个性化非球面IOL的应用及未来新型非球面IOL的设计提供参考依据。
试读结束,您可以通过登录机构账户或个人账户后获取全文阅读权限。
参考文献
[1]
Superstein R Boyaner D Overbury O Functional complaints,visual acuity spatial contrast sensitivity,and glare disability in preoperative and postoperative cataract patients[J]J Cataract Refract Surg 199925(4)∶575-581. DOI: 10.1016/s0886-3350(99)80059-5 .
返回引文位置Google Scholar
百度学术
万方数据
[2]
兰长骏廖萱重视白内障患者视觉质量的评估[J]中华实验眼科杂志 201836(5)∶326-329. DOI: 10.3760/cma.j.issn.2095-0160.2018.05.002 .
返回引文位置Google Scholar
百度学术
万方数据
Lan CJ Liao X Focus on the evaluation of visual quality in cataract patients[J]Chin J Exp Ophthalmol 201836(5)∶326-329. DOI: 10.3760/cma.j.issn.2095-0160.2018.05.002 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[3]
McLellan JS Marcos S Prieto PM et al. Imperfect optics may be the eye's defence against chromatic blur[J]Nature 2002417(9)∶174-176. DOI: 10.1038/417174a .
返回引文位置Google Scholar
百度学术
万方数据
[4]
Guirao A Redondo M Artal P Optical aberrations of the human cornea as a function of age[J]J Opt Soc Am (A) 200017(10)∶1697-1702. DOI: 10.1364/josaa.17.001697 .
返回引文位置Google Scholar
百度学术
万方数据
[5]
Navarro R Rozema JJ Tassingnon MJ . Optical changes of the human cornea as a function of age[J]Opt Vis Sci 201390(1)∶587-98. DOI: 10.1097/OPX.0b013e3182928bc6 .
返回引文位置Google Scholar
百度学术
万方数据
[6]
Savini G Schiano-Lomoriello D Hoffer KJ . Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras[J]J Cataract Refract Surg 201844(4)∶471-478. DOI: 10.1016/j.jcrs.2018.02.015 .
返回引文位置Google Scholar
百度学术
万方数据
[7]
Holladay JT Piers PA Koranyi G et al. A new intraocular design to reduce spherical aberration in pseudophakic eyes[J]J Refract Surg 200218(6)∶683-691.
返回引文位置Google Scholar
百度学术
万方数据
[8]
Beiko GH Haigis W Steinmueller A Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values[J]J Cataract Refract Surg 200733(5)∶848-858. DOI: 10.1016/j.jcrs.2007.01.035 .
返回引文位置Google Scholar
百度学术
万方数据
[9]
Lim KL Fam HB . Ethnic differences in higher-order aberrations:spherical aberration in the South East Asian Chinese eye[J]J Cataract Refract Surg 200935(12)∶2144-2148. DOI: 10.1016/j.jcrs.2009.06.031 .
返回引文位置Google Scholar
百度学术
万方数据
[10]
童女侠赵云娥王勤美角膜前表面四阶球差的分布及其相关因素分析[J]中华眼科杂志 200743(8)∶684-687. DOI: 10.3760/j.issn.0412-4081.2007.08.004 .
返回引文位置Google Scholar
百度学术
万方数据
Tong NX Zhao YE Wang QM et al. Distribution of human anterior corneal spherical aberration and its related factors[J]Chin J Ophthalmol 200743(8)∶684-687. DOI: 10.3760/j.issn:0412-4081.2007.08.004 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[11]
元力鲍永珍单纯老年性白内障人群角膜球面像差分析[J]中华眼科杂志 201450(2)∶100-104. DOI: 10.3760/cma.j.issn.0412-4081.2014.02.005 .
返回引文位置Google Scholar
百度学术
万方数据
Yuan L Bao YZ . Analysis of the c orneal spherical aberration in people with senile cataract [J]Chin J Ophthalmol 201450(2)∶100-104. DOI: 10.3760/cma.j.issn.0412-4081.2014.02.005 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[12]
Wang L Dai E Koch DD et al. Optical aberrations of the human anterior cornea[J]J Cataract Refract Surg 200329(8)∶1514-1521. DOI: 10.1016/So886-3350(99)80059-5 .
返回引文位置Google Scholar
百度学术
万方数据
[13]
Shimozono M Uemura A Hirami Y et al. Corneal spherical aberration of eyes with cataract in a Japanese population[J]J Refract Surg 201026(6)∶457-459. DOI: 10.3928/1081597X-20100212-03 .
返回引文位置Google Scholar
百度学术
万方数据
[14]
Amano S Amano Y Yamagami S et al. Age-related changes in corneal and ocular higher-order wavefront aberrations[J]Am J Ophthalmol 200437(6)∶988-992. DOI: 10.1016/j.ajo.2004.01.005 .
返回引文位置Google Scholar
百度学术
万方数据
[15]
de Sanctis U Vinai L Bartoli E et al. Total spherical aberration of the cornea in patients with cataract[J]Opt Vis Sci 201491(10)∶1251-1258. DOI: 10.1097/OPX.0000000000000380 .
返回引文位置Google Scholar
百度学术
万方数据
[16]
许琛琛王勤美陶育华角膜前表面高阶像差与年龄的相关性变化[J]中华眼视光学与视觉科学杂志 201113(3)∶210-213. DOI: 10.3760/cma.j.issn.1674-845X.2011.03.012 .
返回引文位置Google Scholar
百度学术
万方数据
Xu CC Wang QM Tao YH et al. Age-related changes in higher-order aberrations of the corneal anterior surface in a Chinese population[J]Chin J Opt Ophthalmol Vis Sci 201113(3)∶210-213. DOI: 10.3760/cma.j.issn.1674-845X.2011.03.012 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[17]
张耀花王雁窦瑞近视眼角膜生物力学特性与角膜高阶像差的相关性[J]中华实验眼科杂志 201836(5)∶368-372. DOI: 10.3760/cma.j.issn.2095-0160.2018.05.009 .
返回引文位置Google Scholar
百度学术
万方数据
Zhang YH Wang Y Dou R et al. Correlation analysis between corneal biomechanical properties and high-order aberration in myopia[J]Chin J Exp Ophthalmol 201836(5)∶368-372. DOI: 10.3760/cma.j.issn.2095-0160.2018.05.009 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[18]
Levy Y Segal O Avni I et al. Ocular higher-order aberrations in eyes with supernormal vision[J]Am J Ophthalmol 2005139(2)∶225-228. DOI: 10.1016/j.ajo.2004.08.035 .
返回引文位置Google Scholar
百度学术
万方数据
[19]
Amesbury EC Schalhorn SC . Contrast sensitivity and limits of vision[J]Int Ophthalmol Clin 200343(2)∶31-42. DOI: 10.1097/00004397-200343020-00006 .
返回引文位置Google Scholar
百度学术
万方数据
[20]
蔡芳菲郑广瑛王华君角膜Q值引导下个体化人工晶状体植入术后视觉质量的临床观察[J]中华眼科杂志 201553(11)∶814-820. DOI: 10.3760/cma.j.issn.0412-4081.2017.11.004 .
返回引文位置Google Scholar
百度学术
万方数据
Cai FF Zheng GY Wang HJ et al. Clinical observation of visual quality after the individual implantation of intraocular lens guided by corneal Q value[J]Chin J Exp Ophthalmol 201553(11)∶814-820. DOI: 10.3760/cma.j.issn.0412-4081.2017.11.004 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[21]
马瑶马忠旭高原高阶像差及散射光对非球面IOL眼视网膜成像质量的影响[J]中华实验眼科杂志 201634(3)∶254-259. DOI: 10.3760/cma.j.issn.2095-0160.2016.03.013 .
返回引文位置Google Scholar
百度学术
万方数据
Ma Y Ma ZX Gao Y et al. Effect of high-order aberrations and scattered light on visual quality in pseudophakic eyes with aspheric monofocal IOLs[J]Chin J Exp Ophthalmol 201634(3)∶254-259. DOI: 10.3760/cma.j.issn.2095-0160.2016.03.013 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
备注信息
A
李筱荣,Email: nc.defudabe.umtgnoroaixil
B
所有作者均声明不存在任何利益冲突
C
山西省卫生健康委员会科研基金项目 (2015069)
评论 (0条)
注册
登录
时间排序
暂无评论,发表第一条评论抢沙发
MedAI助手(体验版)
文档即答
智问智答
机器翻译
回答内容由人工智能生成,我社无法保证其准确性和完整性,该生成内容不代表我们的态度或观点,仅供参考。
生成快照
文献快照

你好,我可以帮助您更好的了解本文,请向我提问您关注的问题。

0/2000

《中华医学会杂志社用户协议》 | 《隐私政策》

《SparkDesk 用户协议》 | 《SparkDesk 隐私政策》

网信算备340104764864601230055号 | 网信算备340104726288401230013号

技术支持:

历史对话
本文全部
还没有聊天记录
设置
模式
纯净模式沉浸模式
字号