临床研究
ENGLISH ABSTRACT
区域折射型多焦点人工晶状体植入术与单焦点人工晶状体植入术中长期视觉质量比较
单玉琴
郑广瑛
李莉
陆文龙
作者及单位信息
·
DOI: 10.3760/cma.j.cn115985-20190902-00379
Comparison of medium and long term visual quality between regional refractive multifocal intraocular lens implantation and unifocal intraocular lens implantation
Shan Yuqin
Zheng Guangying
Li Li
Lu Wenlong
Authors Info & Affiliations
Shan Yuqin
Department of Ophthalmology, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
Zheng Guangying
Department of Ophthalmology, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
Li Li
Department of Ophthalmology, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China
Lu Wenlong
School of Medical Technology and Engineering, Henan University of Science and Technology, Luoyang 471000, China
·
DOI: 10.3760/cma.j.cn115985-20190902-00379
1126
399
0
0
7
2
PDF下载
APP内阅读
摘要

目的观察区域折射型多焦点人工晶体(MIOL)植入术后中长期视觉质量,并与单焦点人工晶状体(SIOL)植入术进行比较。

方法采用队列研究方法,纳入2016年8月至2017年8月在郑州大学第一附属医院就诊的白内障患者108例141眼,根据植入的IOL分为MIOL组55例76眼和SIOL组53例65眼。术后2年对2个组患者术眼裸眼远、中、近视力,矫正远视力,等效球镜进行检查;绘制术眼离焦曲线;采用i-Trace视觉质量分析仪测定术眼全眼高阶像差、Strehl比值、调制传递函数(MTF);采用CSV-1000对比敏感度仪评估术眼对比敏感度;采用美国《MIOL植入术后生活质量调查表》汉化版对2个组患者视觉质量进行比较。

结果术后2年MIOL组裸眼中、近视力优于SIOL组,差异均有统计学意义(均 P<0.05)。术后2年平均离焦曲线结果显示MIOL组于0.0 D和-3.0 D处出现2个峰值,且在0.0~-3.0 D之间形成宽平台,下降趋势平缓。5 mm瞳孔直径下,MIOL组全眼总高阶像差、慧差、三叶草、二阶散光值高于SIOL组,差异均有统计学意义(均 P<0.05)。MIOL组Strehl比值小于SIOL组,差异有统计学意义( P<0.05)。5 mm瞳孔直径下,MIOL组在5、10、15、20、25和30 c/d空间频率的MTF值稍小于SIOL组,但差异均无统计学意义(均 P>0.05)。2个组3、6、12和18 c/d空间频率的对比敏感度在明视、暗视及有、无眩光状态下差异均无统计学意义(均 P>0.05)。MIOL组55例患者中54例脱镜,占98.18%,SIOL组53例患者中28例脱镜,占52.83%,差异有统计学意义( χ 2=30.37, P<0.01)。MIOL组55例患者中4例出现眩光、光晕等视觉干扰症状,占7.27%,SIOL组53例患者中1例出现视觉干扰症状,占1.89%,差异无统计学意义( χ 2=0.76, P=0.382)。MIOL组在近距离、中等距离视物及总体视力方面的满意度评分高于SIOL组,差异均有统计学意义(均 P<0.05)。

结论与SIOL植入术比较,区域折射型MIOL植入术可提供良好且稳定的全程视力和较好的对比敏感度,且光学干扰现象发生率低,术后满意度较高。

多焦点人工晶状体;晶状体植入,眼内;波前像差;调制传递函数;对比敏感度
ABSTRACT

ObjectiveTo observe the clinical effect of medium and long term visual quality after regional refractive multifocal intraocular lens (MIOL) implantation and compared with that of single focal intraocular lens (SMOL) implantation.

MethodsA cohort study was conducted with 108 patients (141 eyes) who had undergone MIOL and SIOL implantation in First Affiliated Hospital of Zhengzhou University from August 2016 to August 2017.According to the implanted IOL, the patients were divided into the MIOL group (55 patients 76 eyes) and the SIOL group (53 patients 65 eyes). At 2 years after operation, the parameters of uncorrected far, intermediate and near vision, as well as corrected distant vision were assessed; the spherical equivalen was checked; the defocus curve of the operation eye was drawn; the high order aberrations (HOAs), Strehl ratio and modulation transfer function (MTF) were measured by i-Trace visual quality analyzer; contrast sensitivity of eyes was evaluated by a CSV-1000 contrast sensitivity instrument; visual quality between the two groups was compared by using the Chinese version of the American questionnaire on quality of Life after MIOL.This study was approved by the Ethics Committee of the First Affiliated Hospital of Zhengzhou University.Written informed consent was obtained from each patient prior to any medical examination.

ResultsThe uncorrected intermediate and near visual acuity in the MIOL group was better than that in the SIOL group, with statistically significant difference(both at P<0.05). Two years after operation, the average defocus curve showed that there were two peaks at 0.0 D and -3.0 D in the MIOL group, and formed a wide platform between 0.0 and -3.0 D, and the downward trend was gentle.Under the pupil diameter of 5 mm, HOAs, coma, trefoil and secondary astigmatism in the MIOL group were higher than those in the SIOL group (all at P<0.05). Strehl ratio in the MIOL group was significantly lower than that in the SIOL group, with statistically significant difference ( P<0.05). Under the pupil diameter of 5 mm, MTF values of spatial frequencies of 5, 10, 15, 20, 25 and 30 c/d in the MIOL group were slightly lower than those in the SIOL group, without statistically significant differences (all at P>0.05). There was no significant difference in contrast sensitivity (3, 6, 12 and 18 c/d) between the two groups under photopic or mesopic conditions and with or without glare (all at P>0.05). The proportion of glasses removed in the MIOL group was 98.18%, which was significantly higher than that in the SIOL group (52.83%) by questionnaire ( χ 2=30.37, P<0.01). The incidence of visual interference symptoms, such as glare and halo was 7.27% (4/55) in the MIOL group and 1.89% (1/53) in the SIOL group, respectively, with no statistically significant difference ( χ 2=0.76, P=0.382). The satisfaction scores of vision at near distance vision, medium distance vision and overall visual acuity in the MIOL group were higher than that in the SIOL group, with statistically significant differences (all at P<0.05).

ConclusionsCompared with SIOL implantation, regional refraction MIOL implantation can provide better and more stable mediate and near vision, a better contrast sensitivity, a lower incidence of optical interference and a higher postoperative satisfaction.

Multifocal intraocular lenses;Lens implantation, intraocular;Wavefront aberration;Modulation transfer function;Contrast sensitivity
Zheng Guangying, Email: nc.defudabe.uzzygzzz
引用本文

单玉琴,郑广瑛,李莉,等. 区域折射型多焦点人工晶状体植入术与单焦点人工晶状体植入术中长期视觉质量比较[J]. 中华实验眼科杂志,2020,38(04):348-354.

DOI:10.3760/cma.j.cn115985-20190902-00379

PERMISSIONS

Request permissions for this article from CCC.

评价本文
*以上评分为匿名评价
白内障超声乳化联合人工晶状体(intraocular lens,IOL)植入是目前治疗白内障的有效方法。传统单焦点人工晶状体(single focal intraocular lens,SIOL)可为患者提供良好的远视力,但中、近视力较差,对患者日常生活和工作造成诸多不便。多焦点人工晶状体(multifocal intraocular lens,MIOL)通过其光学区光线的衍射或折射产生多个焦点,可提供远、中、近全程视力 [ 1 , 2 ]。目前,MIOL包括折射型、衍射型及折射-衍射混合型 [ 3 ]。3种类型的IOL远、中、近视力因多焦点光学区设计的不同而有所不同,均能提供良好的全程视力。近年来关于折射型MIOL的术后视觉质量的报道较多,但相关的中长期视觉质量研究较少。本研究对区域折射型MIOL与SIOL植入术后术眼的视觉质量进行比较,为临床上IOL的选择提供参考。
试读结束,您可以通过登录机构账户或个人账户后获取全文阅读权限。
参考文献
[1]
Jiang Y Bu S Tian F et al. Long-term clinical outcomes after mix and match implantation of two multifocal intraocular lenses with different adds[J/OL]J Ophthalmol 201920196789263[2019-08-15]https://www.geenmedical.com/article?id=30755802&type=true. DOI: 10.1155/2019/6789263 .
返回引文位置Google Scholar
百度学术
万方数据
[2]
Pandit RT . Monocular clinical outcomes and range of near vision following cataract surgery with implantation of an extended depth of focus intraocular lens[J/OL]J Ophthalmol 201820188205824[2019-08-18]https://www.geenmedical.com/article?id=30647964&type=true. DOI: 10.1155/2018/8205824 .
返回引文位置Google Scholar
百度学术
万方数据
[3]
Alio J Plaza-Puche AB Férnandez-Buenaga R et al. Multifocal intraocular lenses:an overview[J]Surv Ophthalmol 201762611-634. DOI: 10.1016/j.survophthal.2017.03.005 .
返回引文位置Google Scholar
百度学术
万方数据
[4]
Berdahl JP Hardten DR Kramer BA et al. Effect of astigmatism on visual acuity after multifocal versus monofocal intraocular lens implantation[J]J Cataract Refract Surg 2018441192-1197. DOI: 10.1016/j.jcrs.2018.06.048 .
返回引文位置Google Scholar
百度学术
万方数据
[5]
Cochener B Boutillier G Lamard M et al. A comparative evaluation of a new generation of diffractive trifocal and extended depth of focus intraocular lenses[J]J Refract Surg 201834507-514. DOI: 10.3928/1081597X-20180530-02 .
返回引文位置Google Scholar
百度学术
万方数据
[6]
Pilger D Homburg D Brockmann T et al. Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens[J]Euro J Ophthalmol 201828(8)∶1369-1372. DOI: 10.1177/1120672118766809 .
返回引文位置Google Scholar
百度学术
万方数据
[7]
Alió JL Plaza-Puche AB Montalban R et al. Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lens[J]J Cataract Refract Surg 201238(6)∶978-985. 10.1016/j.jcrs.2011.12.033 .
返回引文位置Google Scholar
百度学术
万方数据
[8]
Böhm M Petermann K Hemkeppler E et al. Defocus curves of 4 presbyopia-correcting IOL designs:Diffractive panfocal,diffractive trifocal,segmental refractive,and extended-depth-of-focus[J]J Cataract Refract Surg 2019451625-1636. DOI: 10.1016/j.jcrs.2019.07.014 .
返回引文位置Google Scholar
百度学术
万方数据
[9]
Camps VJ Tolosa A Piñero DP et al. In vitro aberrometric assessment of a multifocal intraocular lens and two extended depth of focus IOLs [J/OL]J Ophthalmol 201720177095734[2019-08-21]https://www.geenmedical.com/article?id=29318040&type=true. DOI: 10.1155/2017/7095734 .
返回引文位置Google Scholar
百度学术
万方数据
[10]
Savini G Balducci N Carbonara C et al. Functional assessment of a new extended depth-of-focus intraocular lens[J]Eye (London) 201933(3)∶404-410. DOI: 10.1038/s41433-018-0221-1 .
返回引文位置Google Scholar
百度学术
万方数据
[11]
Ekici Gok Z Gunduz A Cankaya C Effect of fasting on contrast sensitivity in healthy males[J]J Ophthalmic Vis Res 201914315-320. DOI: 10.18502/jovr.v14i3.4789 .
返回引文位置Google Scholar
百度学术
万方数据
[12]
Robert MM Alió JL . Distance and near contrast sensitivity function after multifocal intraocular lens implantation[J]J Cataract Refract Surg 200329(4)∶703-711. DOI: 10.1016/s0886-3350(02)01648-6 .
返回引文位置Google Scholar
百度学术
万方数据
[13]
Alió JL Piñero DP Plaza-Puche AB et al. Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens[J]J Cataract Refract Surg 201137241-250. DOI: 10.1016/j.jcrs.2010.08.043 .
返回引文位置Google Scholar
百度学术
万方数据
[14]
Pedrotti E Mastropasqua R Bonetto J et al. Quality of vision,patient satisfaction and long-term visual function after bilateral implantation of a low addition multifocal intraocular lens[J]Int Ophthalmol 2018381709-1716. DOI: 10.1007/s10792-017-0652-x .
返回引文位置Google Scholar
百度学术
万方数据
[15]
Fu Y Kou J Chen D et al. Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses[J]J Cataract Refract Surg 2019451258-1264. DOI: 10.1016/j.jcrs.2019.04.003 .
返回引文位置Google Scholar
百度学术
万方数据
[16]
Lee CY Huang JY Sun CC et al. Correlation and predictability of ocular aberrations and the visual outcome after quadrifocal intraocular lens implantation:a retrospective longitudinal study[J]BMC Ophthalmol 201919188-192. DOI: 10.1186/s12886-019-1195-x .
返回引文位置Google Scholar
百度学术
万方数据
[17]
Gyldenkerne A Ivarsen A Hjortdal J Optical and visual quality after small-incision lenticule extraction[J]J Cataract Refract Surg 20194554-61. DOI: 10.1016/j.jcrs.2018.08.026 .
返回引文位置Google Scholar
百度学术
万方数据
[18]
Zhao Y Wang Z Tian X et al. Comparative study of visual function and ocular aberrations of two different one-piece designed hydrophilic acrylic intraocular lens[J]Int Ophthalmol 201738(21)∶1-7. DOI: 10.1007/s10792-017-0578-3 .
返回引文位置Google Scholar
百度学术
万方数据
[19]
Xu J Zheng T Lu Y Effect of decentration on the optical quality of monofocal,extended depth of focus,and bifocal intraocular lenses[J]J Refract Surg 201935484-492. DOI: 10.3928/1081597X-20190708-02 .
返回引文位置Google Scholar
百度学术
万方数据
[20]
Tan QQ Lin J Tian J et al. Objective optical quality in eyes with customized selection of aspheric intraocular lens implantation[J]BMC Ophthalmol 201919152-157. DOI: 10.1186/s12886-019-1162-6 .
返回引文位置Google Scholar
百度学术
万方数据
[21]
崔嵬杨松霖晏晓明区域折射型多焦点人工晶状体与非球面单焦点人工晶状体植入术后患者客观视觉质量的短期对比研究[J]中华眼科医学杂志:电子版 20188(3)∶103-109. DOI: 10.3877/cma.j.issn.2095-2007.2018.03.002 .
返回引文位置Google Scholar
百度学术
万方数据
Cui W Yang SL Yan XM . A short-term comparative study of objective visual quality between regional refractive multifocal intraocular lens and aspherical unifocal intraocular lens implantation[J]Chin J Ophthalmol Med:Elec Edi 20188(3)∶103-109. DOI: 10.3877/cma.j.issn.2095-2007.2018.03.002 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[22]
孙岩秀郝燕生解江冰多焦点人工晶状体Nd:YAG激光损伤后光学成像质量变化[J]中华实验眼科杂志 201836(3)∶176-180. DOI: 10.3760/cma.j.issn.2095-0160.2018.03.004 .
返回引文位置Google Scholar
百度学术
万方数据
Sun YX Hao YS Xie JB et al. Changes of optical imaging quality of multifocal intraocular lens after Nd:YAG laser injury[J]Chin J Exp Ophthalmol 201836(3)∶176-180. DOI: 10.3760/cma.j.issn.2095-0160.2018.03.004 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[23]
林志博黄芳潘安鹏区域折射型多焦点人工晶状体植入术后视觉质量的临床研究[J]中华眼视光学与视觉科学杂志 201719(8)∶482-487. DOI: 10.3760/cma.j.issn.1674-845X.2017.08.006 .
返回引文位置Google Scholar
百度学术
万方数据
Lin ZB Huang F Pan AP et al. Clinical study of visual quality after regional refractive multifocal intraocular lens implantation[J]Chin J Opt Ophthalmol Vis Sci 201719(8)∶482-487. DOI: 10.3760/cma.j.issn.1674-845X.2017.08.006 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
备注信息
A
郑广瑛,Email: nc.defudabe.uzzygzzz
B
所有作者均声明不存在任何利益冲突
评论 (0条)
注册
登录
时间排序
暂无评论,发表第一条评论抢沙发
MedAI助手(体验版)
文档即答
智问智答
机器翻译
回答内容由人工智能生成,我社无法保证其准确性和完整性,该生成内容不代表我们的态度或观点,仅供参考。
生成快照
文献快照

你好,我可以帮助您更好的了解本文,请向我提问您关注的问题。

0/2000

《中华医学会杂志社用户协议》 | 《隐私政策》

《SparkDesk 用户协议》 | 《SparkDesk 隐私政策》

网信算备340104764864601230055号 | 网信算备340104726288401230013号

技术支持:

历史对话
本文全部
还没有聊天记录
设置
模式
纯净模式沉浸模式
字号