两种新型扫频光相干生物测量仪对近视患者眼生物测量值一致性评价
李金
庞辰久
孟志红
代丽娟
张波
范琪
作者及单位信息
·
DOI: 10.3760/cma.j.cn115989-20190509-00210
Consistency of two new swept-source optical coherent biometry in myopia
Li Jin
Pang Chenjiu
Meng Zhihong
Dai Lijuan
Zhang Bo
Fan Qi
Authors Info & Affiliations
Li Jin
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
Pang Chenjiu
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
Meng Zhihong
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
Dai Lijuan
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
Zhang Bo
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
Fan Qi
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Institute, Henan Eye Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, China
·
DOI: 10.3760/cma.j.cn115989-20190509-00210
406
61
0
0
0
0
PDF下载
APP内阅读
摘要

眼部生物测量对人工晶状体度数计算、原发性闭角型青光眼早期诊断、屈光手术前适应证的筛选极为重要。IOLMaster是临床上常用的眼部生物测量工具,近年来出现的IOLMaster700通过扫频光相干断层扫描(swept source optical coherence tomography,SS-OCT)技术在测量眼球参数的同时获取黄斑部OCT图像,精确性高。OA-2000作为另一种新型扫频光相干生物测量仪,也通过快速扫描的扫频光源和光电探测器来识别波长相关的干扰信号,扫描速度快,具有较高的检出率和可靠度 [ 1 , 2 , 3 ] 。目前,关于这2种设备眼前节测量结果比较的研究鲜有报道。本研究旨在比较IOLMaster700与OA-2000的眼前节生物测量值并分析其测量值的一致性,为临床应用提供参考。

引用本文

李金,庞辰久,孟志红,等. 两种新型扫频光相干生物测量仪对近视患者眼生物测量值一致性评价[J]. 中华实验眼科杂志,2020,38(06):487-488.

DOI:10.3760/cma.j.cn115989-20190509-00210

PERMISSIONS

Request permissions for this article from CCC.

评价本文
*以上评分为匿名评价
眼部生物测量对人工晶状体度数计算、原发性闭角型青光眼早期诊断、屈光手术前适应证的筛选极为重要。IOLMaster是临床上常用的眼部生物测量工具,近年来出现的IOLMaster700通过扫频光相干断层扫描(swept source optical coherence tomography,SS-OCT)技术在测量眼球参数的同时获取黄斑部OCT图像,精确性高。OA-2000作为另一种新型扫频光相干生物测量仪,也通过快速扫描的扫频光源和光电探测器来识别波长相关的干扰信号,扫描速度快,具有较高的检出率和可靠度 [ 1 , 2 , 3 ]。目前,关于这2种设备眼前节测量结果比较的研究鲜有报道。本研究旨在比较IOLMaster700与OA-2000的眼前节生物测量值并分析其测量值的一致性,为临床应用提供参考。
试读结束,您可以通过登录机构账户或个人账户后获取全文阅读权限。
参考文献
[1]
Asena L , Akman A , Güngör SG et al. Comparison of keratometry obtained by a swept source OCT-based biometer with a standard optical biometer and Scheimpflug imaging[J]Curr Eye Res 201843(7)∶882-888. DOI: 10.1080/02713683.2018.1458881 .
返回引文位置Google Scholar
百度学术
万方数据
[2]
Huang J , Savini G , Hoffer KJ et al. Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster[J]Br J Ophthalmol 2017101(4)∶493-498. DOI: 10.1136/bjophthalmol-2016-308352 .
返回引文位置Google Scholar
百度学术
万方数据
[3]
兰长骏彭悦廖萱扫频光相干断层扫描生物测量仪在白内障中的应用[J]中华实验眼科杂志 201937(2)∶123-128. DOI: 10.3760/cma.j.issn.2095-0160.2019.02.010 .
返回引文位置Google Scholar
百度学术
万方数据
Lan CJ , Peng Y , Liao X Application of swept-source optical coherence tomography biometer in cataract[J]Chin J Exp Ophthalmol 201937(2)∶123-128. DOI: 10.3760/cma.j.issn.2095-0160.2019.02.010 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[4]
Goebels S , Pattmöller M , Eppig T et al. Comparison of 3 biometry devices in cataract patients[J]J Cataract Refract Surg 201541(11)∶2387-2393. DOI: 10.1016/j.jcrs.2015.05.028 .
返回引文位置Google Scholar
百度学术
万方数据
[5]
Kunert KS , Peter M , Blum M et al. Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry[J]J Cataract Refract Surg 201642(1)∶76-83. DOI: 10.1016/j.jcrs.2015.07.039 .
返回引文位置Google Scholar
百度学术
万方数据
[6]
Kohlhaas M , Boehm AG , Spoerl E et al. Effect of central corneal thickness,corneal curvature,and axial length on applanation tonometry[J]Arch Ophthalmol 2006124(4)∶471-476. DOI: 10.1001/archopht.124.4.471 .
返回引文位置Google Scholar
百度学术
万方数据
[7]
Malyugin BE , Shpak AA , Pokrovskiy DF . Accommodative changes in anterior chamber depth in patients with high myopia[J]J Cataract Refract Surg 201238(8)∶1403-1407. DOI: 10.1016/j.jcrs.2012.04.030 .
返回引文位置Google Scholar
百度学术
万方数据
[8]
Kongsap P Comparison of a new optical biometer and a standard biometer in cataract patients[J]Eye Vis (Lond) 2016327. DOI: 10.1186/s40662-016-0059-1 .
返回引文位置Google Scholar
百度学术
万方数据
备注信息
A
庞辰久,Email: mocdef.uabhos999jcgnap
B
所有作者均声明不存在利益冲突
评论 (0条)
注册
登录
时间排序
暂无评论,发表第一条评论抢沙发
MedAI助手(体验版)
文档即答
智问智答
机器翻译
回答内容由人工智能生成,我社无法保证其准确性和完整性,该生成内容不代表我们的态度或观点,仅供参考。
生成快照
文献快照

你好,我可以帮助您更好的了解本文,请向我提问您关注的问题。

0/2000

《中华医学会杂志社用户协议》 | 《隐私政策》

《SparkDesk 用户协议》 | 《SparkDesk 隐私政策》

网信算备340104764864601230055号 | 网信算备340104726288401230013号

技术支持:

历史对话
本文全部
还没有聊天记录
设置
模式
纯净模式沉浸模式
字号