两种频域眼前节OCT测量角膜厚度和角膜上皮厚度的差异和一致性比较
王闯
王浩
庞辰久
作者及单位信息
·
DOI: 10.3760/cma.j.cn115989-20210209-00104
Differences in corneal thickness and corneal epithelial thickness measured by two kinds of frequency domain anterior segment OCT and the consistency between them
Wang Chuang
Wang Hao
Pang Chenjiu
Authors Info & Affiliations
Wang Chuang
Department of Ophthalmology, People's Hospital of Henan University, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou 450003, China
Wang Hao
Department of Ophthalmology, People's Hospital of Henan University, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou 450003, China
Pang Chenjiu
Department of Ophthalmology, People's Hospital of Henan University, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou 450003, China
·
DOI: 10.3760/cma.j.cn115989-20210209-00104
0
0
0
0
0
0
PDF下载
APP内阅读
摘要

目的比较2种高分辨率频域眼前节光相干断层扫描(OCT)RTVue XR-OCT和Cirrus 5000 HD-OCT测量角膜厚度和角膜上皮厚度的差异和一致性。

方法采用横断面研究方法,选取2019年7—9月于河南省立眼科医院就诊的近视及近视散光患者52例52眼,由同一检查者分别使用RTVue XR-OCT和Cirrus 5000 HD-OCT测量角膜中央直径0~2 mm范围中心区(C区),距角膜中央2~5 mm范围内上方(S区)、鼻上方(SN区)、鼻侧(N区)、鼻下方(IN区)、下方(I区)、颞下方(IT区)、颞侧(T区)及颞上方(ST区)的角膜厚度和角膜上皮厚度,比较2种眼前节OCT测量相应区域的角膜厚度和角膜上皮厚度的差异,分析其相关性和一致性。

结果RTVue XR-OCT测量角膜C区、S区、SN区、N区、IN区、I区、IT区、T区和ST区的角膜厚度分别为(521.73±29.85)、(554.31±32.38)、(553.54±33.30)、(546.96±32.05)、(537.54±32.10)、(532.13±31.51)、(528.42±30.38)、(532.25±30.08)和(544.85±30.70)μm,Cirrus 5000 HD-OCT测量的各区域角膜厚度分别为(526.77±30.62)、(555.13±33.32)、(558.08±32.57)、(554.46±31.42)、(548.29±31.84)、(539.69±32.74)、(536.19±32.40)、(533.38±31.90)和(543.83±32.02)μm,2种OCT测量各个区域的角膜厚度差异均无统计学意义(均 P>0.05);2种OCT测量的各区域角膜厚度值均呈强的正相关( r=0.99、0.89、0.95、0.97、0.95、0.93、0.96、0.97、0.92,均 P<0.01);Bland-Altman分析显示,2种OCT测量角膜厚度具有良好的一致性。RTVue XR-OCT测量的各区域角膜上皮厚度分别为(52.06±3.26)、(52.58±3.48)、(53.06±3.56)、(53.75±3.49)、(53.81±3.40)、(53.48±3.35)、(52.96±3.32)、(52.67±3.19)和(53.12±3.15)μm,Cirrus 5000 HD-OCT测量结果分别为(46.75±3.25)、(47.40±3.36)、(47.58±3.64)、(48.85±4.48)、(48.46±4.54)、(48.40±4.96)、(48.06±5.12)、(47.46±3.91)和(48.79±3.90)μm,2种OCT测量的各区域角膜上皮厚度比较差异均有统计学意义(均 P<0.05);2种OCT测量的各区域角膜上皮厚度均无明显相关性( r=0.17、0.08、0.16、0.28、0.20、0.24、0.19、0.21、0.13,均 P>0.05);Bland-Altman分析显示,2种OCT测量角膜上皮厚度的一致性欠佳。

结论RTVue XR-OCT和Cirrus 5000 HD-OCT对角膜厚度测量差异较小,一致性较高,可相互替代;对角膜上皮厚度测量差异较大,一致性较差,不可相互替代。

角膜;角膜上皮;厚度;眼前节;光相干断层扫描;差异性;一致性
ABSTRACT

ObjectiveTo investigate the differences in corneal thickness and corneal epithelial thickness measurements by two kinds of high-resolution frequency domain anterior segment optical coherence tomography (OCT), RTVue XR-OCT and Cirrus 5000 HD-OCT, and to analyze the consistency between them.

MethodsA cross-sectional study was conducted.Fifty-two patients (52 eyes) who were admitted to Henan Eye Hospital from July to September 2019 were enrolled.The corneal thickness and corneal epithelial thickness in various areas including the central area (C area) (2-mm diameter), and 8 concentric corneal areas of 2 to 5-mm diameter, which were the superior area (S area), the superior nasal (SN area), the nasal side area (N area), the inferior nasal area (IN area), the inferior area (I area), the inferior temporal area (IT area), the temporal area (T area) and the superior temporal area (ST area) above the temporal, were measured by the same examiner using RTVue XR-OCT and Cirrus 5000 HD-OCT.The corneal thickness and corneal epithelial thickness measurements were compared to analyze the difference, correlation and consistency between the two kinds of OCT.This study adhered to the Declaration of Helsinki.The study protocol was approved by an Ethics Committee of Henan Eye Hospital (No.HNEECKY-2021[06]). Written informed consent was obtained from each subject prior to any medical examination.

ResultsThe corneal thickness measured by RTVue XR-OCT in C, S, SN, N, IN, I, IT, T, ST areas were (521.73±29.85), (554.31±32.38), (553.54±33.30), (546.96±32.05), (537.54±32.10), (532.13±31.51), (528.42±30.38), (532.25±30.08), (544.85±30.70)μm, respectively, and the corneal thickness in the 9 areas measured by Cirrus 5000 HD-OCT were (526.77±30.62), (555.13±33.32), (558.08±32.57), (554.46±31.42), (548.29±31.84), (539.69±32.74), (536.19±32.40), (533.38±31.90), (543.83±32.02)μm, respectively.There was no significant difference in corneal thickness of various areas between the two kinds of OCT (all at P>0.05), and there were positive correlations between them ( r=0.99, 0.89, 0.95, 0.97, 0.95, 0.93, 0.96, 0.97, 0.92; all at P<0.01). Bland-Altman analysis showed that there was a good consistency of corneal thickness measurements by the two kinds of OCT.The corneal epithelial thickness in C, S, SN, N, IN, I, IT, T, ST areas measured by RTVue XR-OCT were (52.06±3.26), (52.58±3.48), (53.06±3.56), (53.75±3.49), (53.81±3.40), (53.48±3.35), (52.96±3.32), (52.67±3.19), (53.12±3.15) μm, respectively, and the corneal epithelial thickness in the 9 areas measured by Cirrus 5000 HD-OCT were (46.75±3.25), (47.40±3.36), (47.58±3.64), (48.85±4.48), (48.46±4.54), (48.40±4.96), (48.06±5.12), (47.46±3.91), (48.79±3.90)μm, respectively.There were statistically significant differences in the corneal epithelial thickness of various areas measured by the two kinds of OCT (all at P<0.05), and there was no significant correlation between them ( r=0.17, 0.08, 0.16, 0.28, 0.20, 0.24, 0.19, 0.21, 0.13; all at P>0.05). Bland-Altman analysis showed poor consistency of corneal epithelial thickness measurements between the two kinds of OCT.

ConclusionsThere is no significant difference in measuring corneal thickness between the two kinds of OCT and the consistency is high, which means that they can be replaced by each other.There are significant differences in corneal epithelial thickness measurement between them and the consistency is poor, so they are not interchangeable.

Cornea;Epithelium, corneal;Thickness;Anterior eye segment;Tomography, optical coherence;Difference;Consistency
Pang Chenjiu, Email: mocdef.3ab61999jcgnap
引用本文

王闯,王浩,庞辰久. 两种频域眼前节OCT测量角膜厚度和角膜上皮厚度的差异和一致性比较[J]. 中华实验眼科杂志,2022,40(02):151-156.

DOI:10.3760/cma.j.cn115989-20210209-00104

PERMISSIONS

Request permissions for this article from CCC.

评价本文
*以上评分为匿名评价
角膜上皮厚度并非均匀一致,角膜自身可以通过改变角膜上皮的再分布补偿基质表面的不规则。研究表明,在圆锥角膜早期,角膜上皮层即有改变,因此,对角膜上皮厚度的精确测量可以为圆锥角膜的早期诊断提供帮助 [ 1 , 2 , 3 , 4 , 5 ]。评估角膜上皮厚度的方法有高频超声生物显微镜、激光扫描共焦显微镜以及眼前节光相干断层扫描(optical coherence tomography,OCT),前两者均为接触性成像技术,增加了角膜上皮损伤和感染的风险,且因为压迫作用也影响测量的准确性。眼前节OCT技术是基于低相干光原理,可提供角膜的横断面影像,通过其内置的测量工具对上皮厚度进行测量,有较快的扫描速度和较高的分辨率,是一种可靠的无侵入性上皮成像方法,对患者配合程度的要求较低。目前有RTVue XR-OCT(美国Optovue公司)和Cirrus 5000 HD-OCT(德国Carl Zeiss公司)2种频域眼前节OCT可以对角膜上皮厚度进行测量,这2种OCT均有较高的图像分辨率和较快的扫描速度,可对角膜厚度和角膜上皮厚度进行客观、定量测量 [ 6 , 7 , 8 ],对屈光手术适应证的筛选、手术方式选择和圆锥角膜早期诊断具有重要意义,目前尚无这2种OCT对角膜厚度和角膜上皮厚度测量的比较研究。本研究拟采用2种OCT对近视及近视散光患者的角膜厚度和角膜上皮厚度进行测量,对2种仪器测量结果的差异和一致性进行比较分析,以期为临床应用提供依据。
试读结束,您可以通过登录机构账户或个人账户后获取全文阅读权限。
参考文献
[1]
Temstet C Sandali O Bouheraoua N et al. Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus[J]J Cataract Refract Surg 201541(4)∶812-820. DOI: 10.1016/j.jcrs.2014.06.043 .
返回引文位置Google Scholar
百度学术
万方数据
[2]
朱晓博周跃华傅立叶OCT角膜厚度参数在临床前期圆锥角膜筛查中的作用[J]眼科 201322165-169.
返回引文位置Google Scholar
百度学术
万方数据
Zhu XB Zhou YH . The role of the parameters measured with RTVueOCT in the screening of subclinical keratoconus[J]Ophthalmol CHN 201322165-169.
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[3]
赵玉瑾洪佳旭王飞圆锥角膜患者角膜上皮厚度变化的相干光断层扫描研究[J]中华眼科杂志 201450(9)∶665-670. DOI: 10.3760/cma.j.issn.0412-4081.2014.09.007 .
返回引文位置Google Scholar
百度学术
万方数据
Zhao YJ Hong JX Wang F et al. The study of corneal epithelial change in keratoconic eyes with Fourier-domain optical coheren ce tomographic pachymetry [J]Chin J Ophthalmol 201450(9)∶665-670. DOI: 10.3760/cma.j.issn.0412-4081.2014.09.007 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[4]
彭梅胡磾姬戎媛超高分辨率OCT测量角膜上皮厚度在圆锥角膜诊断中的价值[J]中华眼视光视觉科学杂志 201517(1)∶9-13. DOI: 10.3760/cma.j.issn.1674-845X.2015.01.003 .
返回引文位置Google Scholar
百度学术
万方数据
Peng M Hu D Ji RY et al. The role of the corneal epithelial thickness parameters measured with ultra-high resolution optical coherence tomography in the diagnosis of keratoconus[J]Chin J Optom Ophthalmol Vis Sci 201517(1)∶9-13. DOI: 10.3760/cma.j.issn.1674-845X.2015.01.003 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[5]
Catalan S Cadarso L Esteves F et al. Assessment of corneal epithelial thickness in asymmetric keratoconic eyes and normal eyes using Fourier domain optical coherence tomography[J/OL]J Ophthalmol 201620165697343[2021-06-15]https://pubmed.ncbi.nlm.nih.gov/27379181/. DOI: 10.1155/2016/5697343 .
返回引文位置Google Scholar
百度学术
万方数据
[6]
Reinstein DZ Yap TE Archer TJ et al. Comparison of corneal epithelial thickness measurement between Fourier-domain OCT and very high-frequency digital ultrasound[J]J Refract Surg 201531(7)∶438-445. DOI: 10.3928/1081597X-20150623-01 .
返回引文位置Google Scholar
百度学术
万方数据
[7]
Li Y Tan O Brass R et al. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes[J]Ophthalmology 2012119(12)∶2425-2433. DOI: 10.1016/j.ophtha.2012.06.023 .
返回引文位置Google Scholar
百度学术
万方数据
[8]
Baghdasaryan E Tepelus TC Marion KM et al. Evaluation of corneal epithelial thickness imaged by high definition optical coherence tomography in healthy eyes[J]Cornea 201938(1)∶62-66. DOI: 10.1097/ICO.0000000000001745 .
返回引文位置Google Scholar
百度学术
万方数据
[9]
Brandt JD Beiser JA Gordon MO et al. Central corneal thickness and measured IOP response to topical ocular hypotensive medication in the Ocular Hypertension Treatment Study[J]Am J Ophthalmol 2004138(5)∶717-722. DOI: 10.1016/j.ajo.2004.07.036 .
返回引文位置Google Scholar
百度学术
万方数据
[10]
Masiwa LE Moodley V A review of corneal imaging methods for the early diagnosis of pre-clinical keratoconus[J]J Optom 202013(4)∶269-275. DOI: 10.1016/j.optom.2019.11.001 .
返回引文位置Google Scholar
百度学术
万方数据
[11]
Sandali O El Sanharawi M Temstet C et al. Fourier-domain optical coherence tomography imaging in keratoconus:a corneal structural classification[J]Ophthalmology 2013120(12)∶2403-2412. DOI: 10.1016/j.ophtha.2013.05.027 .
返回引文位置Google Scholar
百度学术
万方数据
[12]
Li Y Shekhar R Huang D Corneal pachymetry mapping with high-speed optical coherence tomography[J]Ophthalmology 2006113(5)∶792-799. DOI: 10.1016/j.ophtha.2006.01.048 .
返回引文位置Google Scholar
百度学术
万方数据
[13]
Sin S Simpson TL . The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography[J]Optom Vis Sci 200683(6)∶360-365. DOI: 10.1097/01.opx.0000221388.26031.23 .
返回引文位置Google Scholar
百度学术
万方数据
[14]
Ma XJ Wang L Koch DD . Repeatability of corneal epithelial thickness measurements using Fourier-domain optical coherence tomography in normal and post-LASIK eyes[J]Cornea 201332(12)∶1544-1548. DOI: 10.1097/ICO.0b013e3182a7f39d .
返回引文位置Google Scholar
百度学术
万方数据
[15]
Mansoori T Balakrishna N Repeatability and agreement of central corneal thickness measurement with non-contact methods:a comparative study[J]Int Ophthalmol 201838(3)∶959-966. DOI: 10.1007/s10792-017-0543-1 .
返回引文位置Google Scholar
百度学术
万方数据
[16]
华焱军黄锦海潘超RTVue傅里叶光学相干断层扫描仪测量角膜参数的重复性和准确性评价[J]中华实验眼科杂志 201331(2)∶177-181. DOI: 10.3760/cma.j.issn.2095-0160.2013.02.017 .
返回引文位置Google Scholar
百度学术
万方数据
Hua YJ Huang JH Pan C et al. Repeatability and accuracy of corneal parameters measured by RTVue Fourier-domain optical coherence topography[J]Chin J Exp Ophthalmol 201331(2)∶177-181. DOI: 10.3760/cma.j.issn.2095-0160.2013.02.017 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[17]
Azartash K Kwan J Paugh JR et al. Pre-corneal tear film thickness in humans measured with a novel technique[J]Mol Vis 201117756-767.
返回引文位置Google Scholar
百度学术
万方数据
[18]
Chen Q Wang J Tao A et al. Ultrahigh-resolution measurement by optical coherence tomography of dynamic tear film changes on contact lenses[J]Invest Ophthalmol Vis Sci 201051(4)∶1988-1993. DOI: 10.1167/iovs.09-4389 .
返回引文位置Google Scholar
百度学术
万方数据
[19]
田潇李冰眼前节光相干断层扫描测量下泪新月参数及中央角膜厚度在于眼诊断中的应用[J]中华实验眼科杂志 201937(7)∶532-539. DOI: 10.3760/cma.j.issn.2095-0160.2019.07.008 .
返回引文位置Google Scholar
百度学术
万方数据
Tian X Li B Application of anterior segment optical coherence tomography in the measurement of the parameters of lower tear meniscus and central corneal thickness[J]Chin J Exp Ophthalmol 201937(7)∶532-539. DOI: 10.3760/cma.j.issn.2095-0160.2019.07.008 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
备注信息
A
庞辰久,Email: mocdef.3ab61999jcgnap
B

王闯:参与试验设计、采集和整理数据、统计分析、论文撰写;王浩:参与试验设计、采集数据、统计分析;庞辰久:酝酿和设计试验、研究实施和指导、论文数据分析、对文章内容作批判性审阅和修改

C
所有作者均声明不存在任何利益冲突
评论 (0条)
注册
登录
时间排序
暂无评论,发表第一条评论抢沙发
MedAI助手(体验版)
文档即答
智问智答
机器翻译
回答内容由人工智能生成,我社无法保证其准确性和完整性,该生成内容不代表我们的态度或观点,仅供参考。
生成快照
文献快照

你好,我可以帮助您更好的了解本文,请向我提问您关注的问题。

0/2000

《中华医学会杂志社用户协议》 | 《隐私政策》

《SparkDesk 用户协议》 | 《SparkDesk 隐私政策》

网信算备340104764864601230055号 | 网信算备340104726288401230013号

技术支持:

历史对话
本文全部
还没有聊天记录
设置
模式
纯净模式沉浸模式
字号