临床研究
ENGLISH ABSTRACT
中重度圆锥角膜患者巩膜镜试戴效果评估
范棋
杨凯丽
任胜卫
作者及单位信息
·
DOI: 10.3760/cma.j.cn115989-20230911-00094
Fitting effect of scleral lens for moderate and severe keratoconus
Fan Qi
Yang Kaili
Ren Shengwei
Authors Info & Affiliations
Fan Qi
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou 450003, China
Yang Kaili
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou 450003, China
Ren Shengwei
Department of Ophthalmology, Henan Provincial People's Hospital, Henan Eye Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou 450003, China
·
DOI: 10.3760/cma.j.cn115989-20230911-00094
711
176
0
0
4
0
PDF下载
APP内阅读
摘要

目的比较硬性透气性接触镜(RGPCL)和巩膜镜在中重度圆锥角膜患者中的试戴效果。

方法采用横断面研究方法,纳入2022年9月至2023年9月于河南省立眼科医院圆锥角膜门诊就诊的患者42例52眼。依据陡峭角膜曲率(Ks)值将圆锥角膜分为中度组(48 D≤Ks<55 D)28眼和重度组(Ks≥55 D)24眼。对所有眼分别规范试戴RGPCL和巩膜镜,在裂隙灯显微镜下进行荧光素染色观察及眼前节光学相干断层扫描检查,观察镜片中央和旁中央与角膜之间的距离、镜片中央定位、活动度及周边配适情况;记录最佳矫正视力(BCVA)(LogMAR视力)以及戴镜舒适度、湿润度及视觉清晰度评分。比较同一患者试戴RGPCL和巩膜镜后BCVA、舒适度、湿润度和视觉清晰度评分差异及中度和重度圆锥角膜组间患者BCVA、舒适度、湿润度、视觉清晰度评分和改善值差异。

结果所有患者试戴RGPCL后平均BCVA为0.19(0.10,0.30),舒适度、湿润度和视觉清晰度评分分别为5.5(3.0,7.0)、7.0(5.0,8.0)和7.0(4.0,8.0)分。试戴巩膜镜后BCVA为0.10(0.00,0.10),其舒适度、湿润度和视觉清晰度评分分别为8.0(8.0,9.0)、8.0(8.0,9.0)和8.0(6.0,9.0)分。与试戴RGPCL比较,患者试戴巩膜镜后BCVA、舒适度、湿润度和视觉清晰度评分显著提高,差异均有统计学意义( Z=-5.887、-6.064、-5.705、-5.516,均 P<0.001)。试戴巩膜镜后BCVA与Kmax呈中等强度正相关( r s=0.519, P<0.001),与TCT呈中等强度负相关( r s=-0.535, P<0.001)。试戴巩膜镜的清晰度评分与TCT呈中等强度正相关( r s=0.303, P=0.029)。中度和重度亚组分析中,试戴巩膜镜后BCVA优于RGPCL配适,舒适度、湿润度和视觉清晰度评分高于RGPCL,差异均有统计学意义(均 P<0.05)。与中度组比较,重度组清晰度评分改善更为明显,差异有统计学意义( Z=-3.100, P=0.002)。

结论中重度圆锥角膜患者试戴RGPCL提高BCVA的水平有限,试戴巩膜镜在提高患者BCVA的同时,可以显著改善患者的舒适度、湿润度和视觉清晰度。

圆锥角膜;治疗;视力;巩膜镜;硬性透气性接触镜;清晰度
ABSTRACT

ObjectiveTo compare the fitting effect between rig gas-permeable contact lens (RGPCL) and scleral lenses (SLs) in moderate and severe keratoconus eyes.

MethodsA cross-sectional study was performed.Fifty-two eyes of 42 keratoconus patients were recruited in Henan Eye Hospital from September 2022 to September 2023.Based on steep keratometry (Ks) value, patients were divided into moderate stage (48 D≤Ks<55 D, 28 eyes) and severe stage (Ks≥55 D, 24 eyes). RGPCL and SLs were fitted normatively in all eyes.Fluorescein staining and anterior segment optical coherence tomography were performed under a slit lamp.The distance between the central and lateral centers of the lenses and the cornea, the centering of the lenses, the mobility of the lenses and the peripheral fit of the lenses were observed.Best corrected visual acuity (BCVA) converted to logarithmic minimum angle of resolution, comfort score, wetness score and clarity score were recorded.Differences in the above parameters of each patient between RGPCL and SLs wear were compared.The improvement of the above parameters after RGPCL and SLs wear was compared in moderate and severe patients.This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of Henan Eye Hospital (No.HNEECKY-2019[5]-04). Written informed consent was obtained from each patient before any medical examination.

ResultsAfter RGPCL wear, the mean BCVA, comfort, wetness, and clarity score were 0.19(0.10, 0.30), 5.5(3.0, 7.0) points, 7.0(5.0, 8.0) points and 7.0(4.0, 8.0) points, respectively.After SLs wear, the mean BCVA, comfort score, wetness score and clarity score were 0.10(0.00, 0.10), 8.0(8.0, 9.0) points, 8.0(8.0, 9.0) points and 8.0(6.0, 9.0) points, respectively.Compared with RGPCL wear, the BCVA, comfort score, wetness score and clarity score of SLs were significantly improved ( Z=-5.887, -6.064, -5.705, -5.516; all at P<0.001). There was a moderate positive correlation between BCVA and Kmax after SLs wearing ( r s=0.519, P<0.001), and had a moderate negative correlation with TCT ( r s=-0.535, P<0.001). There was a moderate positive correlation between the clarity score of the SLs and TCT ( r s=0.303, P=0.029). In the moderate and severe subgroup analysis, BCVA, comfort score, wetness score and clarity score were significantly improved after SLs wear compared to RGPCL (all at P<0.05). In addition, the clarity score was significantly improved in severe keratoconus compared to moderate keratoconus ( Z=-3.100, P=0.002).

ConclusionsIn patients with moderate to severe keratoconus, RGPCL can improve BCVA to a limited extent.SLs can significantly improve patients' comfort, wetness and visual clarity while improving their BCVA.

Keratoconus;Therapy;Visual acuity;Scleral lens;Rig gas-permeable contact lens;Clarity
Ren Shengwei, Email: mocdef.3ab614891neriewgnehs
引用本文

范棋,杨凯丽,任胜卫. 中重度圆锥角膜患者巩膜镜试戴效果评估[J]. 中华实验眼科杂志,2023,41(12):1179-1186.

DOI:10.3760/cma.j.cn115989-20230911-00094

PERMISSIONS

Request permissions for this article from CCC.

评价本文
*以上评分为匿名评价
圆锥角膜是一种不断进展的致盲眼病,其特征是角膜变薄和突起,伴有不规则散光和视力低下 [ 1 ]。圆锥角膜一般于青春期开始发病,患者发病年龄小,视力下降较为明显,明显影响患者的学习和生活质量,因此,圆锥角膜患者视力矫正的相关研究备受关注 [ 2 , 3 ]。圆锥角膜早期阶段角膜不规则散光不明显,可以用框架眼镜矫正;中晚期不规则散光加重,框架眼镜矫正效果不佳,角膜接触镜成为改善视力的必要手段并发挥主要作用 [ 4 ]。硬性透气性角膜接触镜(rig gas-permeable contact lens,RGPCL)可以明显提高早期圆锥角膜患者的矫正视力,但中晚期患者角膜显著陡峭,RGPCL仅可部分提高患者视力,会出现部分顶点与镜片接触及周边翘边等现象,很难达到完全配适,且患者自诉异物感、不适感和干眼症状较明显,患者运动或瞬目时镜片会有丢失风险,使得患者对RGPCL配适的总体满意度降低 [ 5 , 6 , 7 ]。巩膜镜可跨过角膜缘在巩膜上着陆,不接触角膜上的致密神经丛,因此患者舒适度明显改善 [ 8 ]。巩膜镜可明显改善患者的矫正视力、舒适度和满意度 [ 9 , 10 ],在国外应用较广,然而国内对于巩膜镜在圆锥角膜中的临床应用研究仍十分有限。本研究拟通过比较RGPCL和巩膜镜矫治中重度圆锥角膜效果,探讨巩膜镜矫治中重度圆锥角膜患者的视力、舒适度、湿润度及视觉清晰度评分,以期为患者提供新的视力矫正方案。
试读结束,您可以通过登录机构账户或个人账户后获取全文阅读权限。
参考文献
[1]
Gomes JA Tan D Rapuano CJ et al. Global consensus on keratoconus and ectatic diseases[J]Cornea 201534(4)∶359369. DOI: 10.1097/ICO.0000000000000408 .
返回引文位置Google Scholar
百度学术
万方数据
[2]
Wang Y Jacobs DS . Role of therapeutic contact lenses in management of corneal disease[J]Curr Opin Ophthalmol 202233(4)∶306310. DOI: 10.1097/ICU.0000000000000859 .
返回引文位置Google Scholar
百度学术
万方数据
[3]
Lim L Lim EWL . Current perspectives in the management of keratoconus with contact lenses[J]Eye (Lond) 202034(12)∶21752196. DOI: 10.1038/s41433-020-1065-z .
返回引文位置Google Scholar
百度学术
万方数据
[4]
Rathi VM Mandathara PS Dumpati S Contact lens in keratoconus[J]Indian J Ophthalmol 201361(8)∶410415. DOI: 10.4103/0301-4738.116066 .
返回引文位置Google Scholar
百度学术
万方数据
[5]
Shorter E Schornack M Harthan J et al. Keratoconus patient satisfaction and care burden with corneal gas-permeable and scleral lenses[J]Optom Vis Sci 202097(9)∶790796. DOI: 10.1097/OPX.0000000000001565 .
返回引文位置Google Scholar
百度学术
万方数据
[6]
Itoi M Itoi M Management of keratoconus with corneal rigid gas-permeable contact lenses[J]Eye Contact Lens 202248(3)∶110114. DOI: 10.1097/ICL.0000000000000876 .
返回引文位置Google Scholar
百度学术
万方数据
[7]
Xue Y Zhou J Chen Z et al. Factors affecting long-term compliance with rigid gas-permeable contact lens wear in patients with keratoconus[J/OL]J Clin Med 202211(4)∶1091[2023-07-26]https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8878038/. DOI: 10.3390/jcm11041091 .
返回引文位置Google Scholar
百度学术
万方数据
[8]
Bergmanson JP Walker MK Johnson LA . Assessing scleral contact lens satisfaction in a keratoconus population[J]Optom Vis Sci 201693(8)∶855860. DOI: 10.1097/OPX.0000000000000882 .
返回引文位置Google Scholar
百度学术
万方数据
[9]
Baudin F Chemaly A Arnould L et al. Quality-of-life improvement after scleral lens fitting in patients with keratoconus[J]Eye Contact Lens 202147(9)∶520525. DOI: 10.1097/ICL.0000000000000821 .
返回引文位置Google Scholar
百度学术
万方数据
[10]
Kreps EO Claerhout I Koppen C The outcome of scleral lens fitting for keratoconus with resolved corneal hydrops[J]Cornea 201938(7)∶855858. DOI: 10.1097/ICO.0000000000001946 .
返回引文位置Google Scholar
百度学术
万方数据
[11]
齐艳胡艳徐珊珊巩膜镜矫正圆锥角膜的临床效果观察[J]中华眼视光学与视觉科学杂志 202224(5)∶364369. DOI: 10.3760/cma.j.cn115909-20210913-00383 .
返回引文位置Google Scholar
百度学术
万方数据
Qi Y Hu Y Xu SS et al. Clinical effect of the scleral lens in the treatment of keratoconus[J]Chin J Optom Ophthalmol Vis Sci 202224(5)∶364369. DOI: 10.3760/cma.j.cn115909-20210913-00383 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[12]
中华医学会眼科学分会角膜病学组中国圆锥角膜诊断和治疗专家共识(2019年)[J]中华眼科杂志 201955(12)∶891895. DOI: 10.3760/cma.j.issn.0412-4081.2019.12.004 .
返回引文位置Google Scholar
百度学术
万方数据
[13]
朱梦杨凯丽徐丽妍圆锥角膜临床特征及其严重程度的影响因素分析[J]中华实验眼科杂志 202341(5)∶484492. DOI: 10.3760/cma.j.cn115989-20220811-00368 .
返回引文位置Google Scholar
百度学术
万方数据
Zhu M Yang KL Xu LY et al. Clinical features of keratoconus and influencing factors of disease severity[J]Chin J Exp Ophthalmol 202341(5)∶484492. DOI: 10.3760/cma.j.cn115989-20220811-00368 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[14]
翟耀华庞辰久任胜卫可视化角膜生物测量仪生物力学指标对圆锥角膜诊断的灵敏度和特异度评估[J]中华实验眼科杂志 201937(7)∶527531. DOI: 10.3760/cma.j.issn.2095-0160.2019.07.007 .
返回引文位置Google Scholar
百度学术
万方数据
Zhai YH Pang CJ Ren SW et al. Evaluation of the sensitivity and specificity of corneal visualization scheimpflug technology biomechanical index in the diagnosis of keratoconus[J]Chin J Exp Ophthalmol 201937(7)∶527531. DOI: 10.3760/cma.j.issn.2095-0160.2019.07.007 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[15]
Yang K Xu L Fan Q et al. Association between corneal stiffness parameter at the first applanation and keratoconus severity[J/OL]J Ophthalmol 202020206667507[2023-07-26]https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7726963/. DOI: 10.1155/2020/6667507 .
返回引文位置Google Scholar
百度学术
万方数据
[16]
Kymes SM Walline JJ Zadnik K et al. Quality of life in keratoconus[J]Am J Ophthalmol 2004138(4)∶527535. DOI: 10.1016/j.ajo.2004.04.031 .
返回引文位置Google Scholar
百度学术
万方数据
[17]
Ling J Qiao G Iovieno A et al. Visual outcomes of cataract surgery in patients with keratoconus using toric and non-toric lenses[J]J Refract Surg 202339(5)∶319325. DOI: 10.3928/1081597X-20230301-01 .
返回引文位置Google Scholar
百度学术
万方数据
[18]
Chen Y Rong H Liu W et al. Agreement of corrected intraocular pressure values between corvis st and pentacam in patients with keratoconus,subclinical keratoconus,and normal cornea[J]Cornea 202140(11)∶14261432. DOI: 10.1097/ICO.0000000000002707 .
返回引文位置Google Scholar
百度学术
万方数据
[19]
Levit A Benwell M Evans B Randomised controlled trial of corneal vs.scleral rigid gas permeable contact lenses for keratoconus and other ectatic corneal disorders[J]Cont Lens Anterior Eye 202043(6)∶543552. DOI: 10.1016/j.clae.2019.12.007 .
返回引文位置Google Scholar
百度学术
万方数据
[20]
Rijal S Hastings GD Nguyen LC et al. The impact of misaligned wavefront-guided correction in a scleral lens for the highly aberrated eye[J]Optom Vis Sci 202097(9)∶732740. DOI: 10.1097/OPX.0000000000001577 .
返回引文位置Google Scholar
百度学术
万方数据
[21]
蓝方方刘伟民赵武校非球面高透氧性硬性透气性角膜接触镜矫正特殊类型屈光不正的临床评价[J]国际眼科杂志 201010(11)∶21182120. DOI: 10.3969/j.issn.1672-5123.2010.11.024 .
返回引文位置Google Scholar
百度学术
万方数据
Lan FF Liu WM Zhao WX et al. Clinical evaluation of non-spherical rigid gas-permeable contact lens for ametropia[J]Int Eye Sci 201010(11)∶21182120. DOI: 10.3969/j.issn.1672-5123.2010.11.024 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[22]
郭寅刘立洲彭丽长期配戴硬性透气性角膜接触镜对不同程度圆锥角膜的矫正效果及安全性评价[J]中华实验眼科杂志 201836(2)∶135139. DOI: 10.3760/cma.j.issn.2095-0160.2018.02.012 .
返回引文位置Google Scholar
百度学术
万方数据
Guo Y Liu LZ Peng L et al. Efficacy and safety of long-term wearing rigid gas permeable contact lens in different degrees of keratoconus eyes[J]Chin J Exp Ophthalmol 201836(2)∶135139. DOI: 10.3760/cma.j.issn.2095-0160.2018.02.012 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[23]
Yuksel Elgin C Iskeleli G Aydin O Effects of the rigid gas permeable contact lense use on tear and ocular surface among keratoconus patients[J]Cont Lens Anterior Eye 201841(3)∶273276. DOI: 10.1016/j.clae.2017.12.013 .
返回引文位置Google Scholar
百度学术
万方数据
[24]
Saraç Ö Kars ME Temel B et al. Clinical evaluation of different types of contact lenses in keratoconus management[J]Cont Lens Anterior Eye 201942(5)∶482486. DOI: 10.1016/j.clae.2019.02.013 .
返回引文位置Google Scholar
百度学术
万方数据
[25]
朱琳张姝贤刘菁华巩膜接触镜的临床应用及研究进展[J]中华眼视光学与视觉科学杂志 202325(6)∶476480. DOI: 10.3760/cma.j.cn115909-20210527-00219 .
返回引文位置Google Scholar
百度学术
万方数据
Zhu L Zhang SX Liu JH et al. Clinical application and research progress of scleral contact lens[J]Chin J Optom Ophthalmol Vis Sci 202325(6)∶476480. DOI: 10.3760/cma.j.cn115909-20210527-00219 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[26]
Carracedo G Blanco MS Martin-Gil A et al. Short-term effect of scleral lens on the dry eye biomarkers in keratoconus[J]Optom Vis Sci 201693(2)∶150157. DOI: 10.1097/OPX.0000000000000788 .
返回引文位置Google Scholar
百度学术
万方数据
[27]
Kollros L Lu N Hillen M et al. Scleral contact lenses fitted to extremely steep corneas[J/OL]J Fr Ophtalmol 202346(2)∶e70e74[2023-08-03]https://pubmed.ncbi.nlm.nih.gov/36670016/. DOI: 10.1016/j.jfo.2022.08.011 .
返回引文位置Google Scholar
百度学术
万方数据
[28]
沙晓通吴志毅陈彬彬巩膜接触镜在圆锥角膜治疗中的临床研究进展[J]中华眼视光学与视觉科学杂志 202325(4)∶312316. DOI: 10.3760/cma.j.cn115909-20210129-00037 .
返回引文位置Google Scholar
百度学术
万方数据
Sha XT Wu ZY Chen BB et al. Clinical research progress of scleral contact lenses in treatment of keratoconus[J]Chin J Optom Ophthalmol Vis Sci 202325(4)∶312316. DOI: 10.3760/cma.j.cn115909-20210129-00037 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[29]
DeLoss KS Fatteh NH Hood CT . Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) scleral device compared to keratoplasty for the treatment of corneal ectasia[J]Am J Ophthalmol 2014158(5)∶974982. DOI: 10.1016/j.ajo.2014.07.016 .
返回引文位置Google Scholar
百度学术
万方数据
[30]
Koppen C Kreps EO Anthonissen L et al. Scleral lenses reduce the need for corneal transplants in severe keratoconus[J]Am J Ophthalmol 20181854347. DOI: 10.1016/j.ajo.2017.10.022 .
返回引文位置Google Scholar
百度学术
万方数据
[31]
Kreps EO Pesudovs K Claerhout I et al. Mini-scleral lenses improve vision-related quality of life in keratoconus[J]Cornea 202140(7)∶859864. DOI: 10.1097/ICO.0000000000002518 .
返回引文位置Google Scholar
百度学术
万方数据
[32]
Yan P Kapasi M Conlon R et al. Patient comfort and visual outcomes of mini-scleral contact lenses[J]Can J Ophthalmol 201752(1)∶6973. DOI: 10.1016/j.jcjo.2016.07.008 .
返回引文位置Google Scholar
百度学术
万方数据
[33]
Akkaya Turhan S Özarslan Özcan D Toker E Use of a mini-scleral lens in patients with keratoconus[J]Turk J Ophthalmol 202050(6)∶339342. DOI: 10.4274/tjo.galenos.2020.56804 .
返回引文位置Google Scholar
百度学术
万方数据
[34]
Romero-Jiménez M Flores-Rodríguez P Utility of a semi-scleral contact lens design in the management of the irregular cornea[J]Cont Lens Anterior Eye 201336(3)∶146150. DOI: 10.1016/j.clae.2012.12.006 .
返回引文位置Google Scholar
百度学术
万方数据
[35]
Severinsky B Behrman S Frucht-Pery J et al. Scleral contact lenses for visual rehabilitation after penetrating keratoplasty:long term outcomes[J]Cont Lens Anterior Eye 201437(3)∶196202. DOI: 10.1016/j.clae.2013.11.001 .
返回引文位置Google Scholar
百度学术
万方数据
[36]
贾旭李志敏谷浩长期佩带角膜接触镜对角膜上皮细胞凋亡的影响[J]中华实验眼科杂志 201331(7)∶674677. DOI: 10.3760/cma.j.issn.2095-0160.2013.07.013 .
返回引文位置Google Scholar
百度学术
万方数据
Jia X Li ZM Gu H Effect of wearing of soft corneal contact lens for long term on apoptosis of corneal epithelial cell[J]Chin J Exp Ophthalmol 201331(7)∶674677. DOI: 10.3760/cma.j.issn.2095-0160.2013.07.013 .
Goto CitationGoogle Scholar
Baidu Scholar
Wanfang Data
[37]
Carracedo G Wang Z Serramito-Blanco M et al. Ocular surface temperature during scleral lens wearing in patients with keratoconus[J]Eye Contact Lens 201743(6)∶346351. DOI: 10.1097/ICL.0000000000000273 .
返回引文位置Google Scholar
百度学术
万方数据
[38]
Barnett M Lien V Li JY et al. Use of scleral lenses and miniscleral lenses after penetrating keratoplasty[J]Eye Contact Lens 201642(3)∶185189. DOI: 10.1097/ICL.0000000000000163 .
返回引文位置Google Scholar
百度学术
万方数据
[39]
Vincent SJ Fadel D Optical considerations for scleral contact lenses:a review[J]Cont Lens Anterior Eye 201942(6)∶598613. DOI: 10.1016/j.clae.2019.04.012 .
返回引文位置Google Scholar
百度学术
万方数据
[40]
Severinsky B Fadel D Davelman J et al. Effect of scleral lenses on corneal topography in keratoconus:a case series of cross-linked versus non-cross-linked eyes[J]Cornea 201938(8)∶986991. DOI: 10.1097/ICO.0000000000002008 .
返回引文位置Google Scholar
百度学术
万方数据
[41]
Badrinarayanan A Balakrishnan AC Dutta R et al. Impact of scleral lens front surface eccentricity on visual acuity,contrast sensitivity,and higher-order aberrations in eyes with keratoconus[J]Eye Contact Lens 202349(9)∶374378. DOI: 10.1097/ICL.0000000000001007 .
返回引文位置Google Scholar
百度学术
万方数据
[42]
Serramito M Carpena-Torres C Carballo J et al. Posterior cornea and thickness changes after scleral lens wear in keratoconus patients[J]Cont Lens Anterior Eye 201942(1)∶8591. DOI: 10.1016/j.clae.2018.04.200 .
返回引文位置Google Scholar
百度学术
万方数据
备注信息
A
任胜卫,Email: mocdef.3ab614891neriewgnehs
B

范棋:采集数据、起草文章、文章修改;杨凯丽:采集数据、分析/解释数据、文章修改;任胜卫:酝酿/设计试验、分析/解释数据、对文章的知识性内容作批评性审阅、文章定稿

C
https://www.chictr.org.cn/,ChiCTR1900023046
D
https://www.chictr.org.cn/,ChiCTR1900023046
E
所有作者均声明不存在利益冲突
F
国家自然科学基金青年科学基金项目 (81200664)
河南省自然科学基金面上项目 (222300420536)
河南省医学科技攻关计划省部共建重点项目 (SBGJ202002028)
河南省中青年卫生健康科技创新杰出青年人才培养项目 (YXKC2020023)
河南省立眼科医院基础研究重点专项 (20JCZD003)
评论 (0条)
注册
登录
时间排序
暂无评论,发表第一条评论抢沙发
MedAI助手(体验版)
文档即答
智问智答
机器翻译
回答内容由人工智能生成,我社无法保证其准确性和完整性,该生成内容不代表我们的态度或观点,仅供参考。
生成快照
文献快照

你好,我可以帮助您更好的了解本文,请向我提问您关注的问题。

0/2000

《中华医学会杂志社用户协议》 | 《隐私政策》

《SparkDesk 用户协议》 | 《SparkDesk 隐私政策》

网信算备340104764864601230055号 | 网信算备340104726288401230013号

技术支持:

历史对话
本文全部
还没有聊天记录
设置
模式
纯净模式沉浸模式
字号